Buildings - Building Code


As referenced by Chapter 30 of the New York City Building Code, the provisions of ASME A with supplements Aa and Ab shall be modified in accordance with this blogger.com section numbers correlate to those in the referenced ASME standard. Refer to the rules of the department for any subsequent additions, modifications or deletions that may have been made to this standard in. *RULE OF CONSTRUCTION OF THE BUILDING CODE REFERENCE STANDARDS Section 1. It shall be a rule of construction for the building code reference standards of the appendix to chapter one of title twenty-seven of the administrative code of the city of New York that references to the sections of the. Title 26 / Subchapter 1 of buildings. 5. The term "department" shall mean the city department of buildings. §[] Seal; judicial notice.-The commissioner may design and adopt a seal for the department, and cause the same to be used in the authentication.




nyc building code pdf download


Nyc building code pdf download


Toggle on amendment styling to see the changes your jurisdiction has made to the adopted base codes. Adjust the size of the code viewer text. This isolates the text of the code and will not affect navigational elements. Bookmark frequently used or relevant sections to your project. Drop in comments to help expand the code and communicate with your team. Always find your place during code research. Help unpack the code with documents from the DOB. Log in. Sign Up.


Please enter a search query. Upgrade to premium. Simplify code analysis. Print chapters, sections, and subsections for frequently used code, nyc building code pdf download. Project pages allow you to export groupings of code across different chapters and publications. Bookmark sections for yourself or for your team. See exactly what's been amended without leaving the code.


NYC Building Code Learn more in the Linked Resources panel on the right. The section numbers correlate to those in the referenced ASME standard. Refer to the rules of the department for any subsequent additionsmodifications or deletions that may have been made to this standard in accordance with Section For the purpose of applying Section 2.


Elevator is classified as freight or passenger. A special operating control function that may be provided for elevators in Occupancy Group I-2 Hospital or other applicable medical facility used to transport a patient in a life or death situation. An elevator located in a building classified in Occupancy Group I-2 Hospital reserved for the "sole" use of vertical transportation of nonambulatory patients who are incapable of self-preservation because of age, physical or mental disability.


Hospital staff or other passengers transporting a patient are permitted to ride with the patient. Such elevators must be operated by a designated attendant and shall meet the requirements of Sections 2. The lowest landing of an elevator or a group of elevators located above the street level. An opening for venting at the top of the elevator hoistway s. A limited space on the elevator lobby between the exterior of the hoistway door and the security door attached to the elevator hoistway.


Delete Section 2. Delete and revise Section 2. Add new Subsection f to Section 2. Add new Subsection e to Section 2. Add new Section 2. The receptacle shall not be used for permanently installed equipment. All elevator hoistway -landing openings shall be provided with entrances that shall guard the full height and width of the openings.


Entrances shall be at least mm 80 in. Delete and revise Subsection a of 2, nyc building code pdf download. Where an elevator is installed in a single blind hoistwaythere shall be installed in the blind portion of the hoistwayin line with the car door, an emergency door at every third floor, but not more than 11 m 36 ft from sill to sill, conforming to the following: a The clear opening shall be at least mm 36 in. For passenger elevators, entrances shall be one of the following types: a Horizontally sliding; b Horizontally swinging, single-section; c Hand- or power-operated vertically nyc building code pdf download that slide up to open.


For freight elevators, entrances shall be one of the following types: a Horizontally sliding; b Swinging, single-section; c Center-opening, two- horizontally swinging, subject to the restrictions of Section 2. Elevator landings provided with a zero clearance vestibule, not to exceed mm 6 in.


Locking devices at the vestibule will be permitted under any one of the following: 1 A red telephone is installed in the vestibule near the elevator doors in the elevator lobby to communicate with the main lobby fire command station or building manager's office or to central service station when the building is not attended. A sign shall be posted near the telephone. Delete and revise Sections 2. Manually operated or self-closing hoistway doors of the vertically or horizontally sliding type, for elevators with automatic or continuous-pressure operation, shall be provided with a vision panel.


In multi doors, the vision panel is required in one only, but is permitted to be placed in all sections. All horizontally swinging elevator nyc building code pdf download shall be provided with vision panels. Vision panels are permitted for any type of hoistway door.


Vision panels shall not be required at the landing of automatic operation elevators equipped with horizontally side sliding car and hoistway doors.


Where required or used, nyc building code pdf download, vision panels shall conform to Sections 2. A security guard shall not be considered doorman service.


Delete and revise Subsection a of Section 2. Bottom guides nyc building code pdf download conform to the following: a The bottom of each panel shall be guided by two or more members. Delete and revise the heading of Section 2. Each type and make of hoistway -door interlock, and car door or gate electric contact shall be of an approved type. Elevators that are operated from within the car only and have manual operated doors that can be opened with a common tool shall have elevator-parking devices installed at that landing.


This device shall be located at a height not greater than 2. Parking devices are not required for elevators having hoistway doors that are automatically unlocked when the car is within the landing zone.


Parking devices shall conform to the following requirements: 1 They shall be mechanically or electrically operated. The car interior lighting shall not be extinguished and must meet the requirements of 3. Delete and revise Subsections a and b of Section 2. Vision panels are not required, but where used, shall: a Be of a total area of not more than 0. Car doors or gates shall be considered to be in the closed position under the following conditions: 1 For horizontally sliding doors or gates, when the clear open space between the leading edge of the door or gate and the nearest face of the jamb does not exceed 25 mm 1 in.


All platform materials exposed to the hoistway shall be either: a Metal; or b Other materials that, in their end use configuration, conform to the following requirements, based on the tests conducted in accordance with the requirements of ASTM E 84, UL or NFPA 1 Flame spread rating of 0 to 50; and 2 Smoke development of 0 to Add new text to Section 2.


Wedge socket assemblies shall be of a design as shown in Fig. Wedge rope sockets are not permitted on counterweighted winding drum machines.


Means shall be provided to retain weights in place in the event of buffer engagement or safety application or if they become broken. Where tie rods are used, a minimum of two 2 shall be provided and they shall pass through all weight sections. Tie rods shall be provided with a lock nut and a cotter pin at each end. Except for safety hooks, where used, compensation means, such as compensating ropes or chains or other mechanical means and their attachments used to tie the counterweight and car together, shall be capable of withstanding, with a factor of safety of five 5any forces nyc building code pdf download which the means is subjected with the elevator at rest.


The maximum suspended weight of compensation means with car or counterweight at the top of its travel and one half-total weight of tension sheave assembly, where used, shall be included. Nyc building code pdf download factor of safety for compensation means shall be based on the proof loadbreaking strengthor test reports, nyc building code pdf download.


Add new Subsections a and b to Section 2. Oil buffers shall be provided with means for determining that the oil level is within the maximum and minimum allowable limits.


Glass sight gauges shall not be used. Each gear case of geared machines shall have access to permit inspection of the contact surfaces of the gears. Add new Subsection d to Section 2. Final terminal-stopping devices shall conform to Section 2.


Add new Items 3 and 4 to Section 2. Top-of-car inspection operation shall conform to Section 2. On all elevators, an emergency stop switch shall be provided in the car, and located in or adjacent to each car operating panel.


When open "STOP" positionthis switch shall cause the electric power to be removed from the elevator driving-machine motor and brake. Emergency stop switches shall: a Be of the manually opened and closed type; b Have red operating handles or buttons; c Be conspicuously and permanently marked "STOP," and shall indicate the "STOP" and "RUN" positions; and d While opened, cause the audible device to sound see Section 2.


Add the following exception to Section 2. Means shall be provided to enable two-way voice communication between the machine room and the interior of the car. Except as set forth in subsection k of this section, smoke detectors installed in accordance with subsections a, b, c or d shall initiate Phase I emergency recall operation.


Smoke detectors may be installed in any other hoistway and shall be installed in hoistways that are sprinklered. After verification of an alarm condition either from the analog addressable smoke detector or from the first detector of cross zoning nyc building code pdf download, the completion of the delayed time period of an analog addressable smoke detector or the activation of both smoke detectors for cross zoning in any elevator lobby, other than the sky lobby, shall cause all automatic elevators servicing the nyc building code pdf download on which the sensing device is activated to return nonstop to the designated or sky lobby level, except as modified by the commissioner.


After verification of an alarm condition either from the analog addressable smoke detector or from the first detector of cross zoning detectors, the completion of the delayed time period of an analog addressable smoke detector or the activation of both smoke detectors for cross zoning in any elevator machine room shall cause all automatic elevators having any equipment located in that machine room, and any associated elevators of a group automatic operation, to return nonstop to the designated or sky lobby level, nyc building code pdf download, except as modified by the commissioner, nyc building code pdf download.


The operation of this subsection shall conform to the requirements of Section 2. In a building equipped throughout with an automatic sprinkler systemthe activation of the waterflow alarm shall cause Phase I emergency recall operation to be initiated Section 2.


It shall become effective only when the designated or sky lobby level Phase I switch Section 2. Car position indicators, where provided, shall remain in service, nyc building code pdf download. Hall position indicators, nyc building code pdf download, where provided, nyc building code pdf download, shall remain inoperative except at the designated level, nyc building code pdf download, sky lobby level and the fire control station, where they shall remain in service for Fire Department operations.


If the button is released prior to the door reaching the normal open position, the doors shall automatically close. Section 2. On cars with two entrances, separate door-open buttons shall be provided for each entrance if both entrances can be opened at the same landing, d Open power-operated doors shall be closed only by momentary pressure on the door close button.


Read More





2017 New York State Building Codes Update

, time: 1:21:09







Nyc building code pdf download


nyc building code pdf download

UpCodes offers a consolidated resource of construction and building code grouped by jurisdiction. Article 10 Precautions During Building Operations [PDF] Article 11 Fire Resistive Construction [PDF] NYC Code [PDF] Navigation ↑ Search a chapter, section, or keyword in the search bar. UpCodes offers a consolidated resource of construction and building code grouped by jurisdiction. Article 10 Precautions During Building Operations [PDF] Article 11 Fire Resistive Construction [PDF] NYC Code [PDF] Navigation ↑ Search a chapter, section, or keyword in the search bar. Jul 31,  · NYC ELECTRICAL (): New York City Building Code Item Preview remove-circle NYC ELECTRICAL (): New York City Building Code by City of New York. Publication date Usage CC0 Universal Topics blogger.com Collection PDF download. download 1 file.